SNA Link/iX Node Managers Guide (30291-90507)
Chapter 2 39
SNA Node and Link Configuration
Data Required from the AS/400 Configuration
SNA/Token Ring Information
For the AS/400 and the HP e3000 to communicate, you must coordinate
the SNA/Token Ring node configuration with the AS/400 configuration.
The HP SNA Products Remote System Configuration Guide explains
this configuration.
Table 2-10 shows the relationships between parameters from the
AS/400 configuration and items in the SNA node configuration file for
an SNA/Token Ring link. Each NMMGR screen field is described later
in this chapter.
Table 2-9 AS/400 Parameter Values for X.25 Link
AS/400 Configuration Parameter Field in NMMGR Screen NMMGR Screen
Name
NETADDR in the line description Remote’s X.25 Network Address X.25 Link Data
Table 2-10 AS/400 Parameter Values for Token Ring Link
AS/400 Configuration Parameter Field in NMMGR Screen NMMGR Screen
Name
MAXFRAME in the line description MAX DATA PU Data
EXCHID in the controller description ID BLK combined with ID NUM PU Data
ADPTADR in the line description for
the AS/400 system
Remote Station Address Token Ring Link Data
SSAP in the controller description for
the AS/400 system
Remote DSAP Token Ring Link Data
DSAP in the controller description for
the HP e3000
Local SSAP Token Ring Link Data
ADPTADR in the controller description
for the HP e3000
Local Station Address Token Ring Link Data
RMTCPNAME in the APPC display
controller description (APPC only)*
Local Control Point Name PU Data
*If APPC is not being configured, HP recommends that you use the PU name in the Local
Control Point Name field.