SNA Link/iX Node Managers Guide (30291-90009)
Table Of Contents
- 1 SNA Links Overview
- 2 SNA Node and Link Configuration
- 3 Logging Configuration
- 4 SNA Node Startup and Shutdown
- 5 SNA Link Troubleshooting
- 6 MPE Commands
- 7 SNA Link Installation Information
- A Messages
- SDLC Link Startup Error Messages
- SDLC Link Driver Error Messages
- SNACONTROL Error Messages
- SNA Transport Error Messages
- SNA Transport Logging Messages
- SDLC Link Shutdown Error Messages
- X.25 Link Failure Error Codes
- X.25 Link Module Configurator Error Codes
- X.25 Link QLLC Internal Error Codes
- NetView Alerts Error Messages
- Network Dump Manager Error Messages
- LAN Error Messages
- B Netview Alerts

178 AppendixA
Messages
SDLC Link Startup Error Messages
17 MESSAGE: Could not unfreeze the configuration data.
CAUSE: Memory problems are occurring.
ACTION: Write down the error information displayed on the console and
call your Hewlett-Packard support contact.
18 MESSAGE: Unable to obtain dump/diag ports.
CAUSE: The Diagnostic User Interface (DUI) software or the Network
Dump Process was not installed properly.
ACTION: Write down the error information displayed on the console and
call your Hewlett-Packard support contact.
19 MESSAGE: Could not create the auxiliary buffer pool.
CAUSE: An internal error has occurred.
ACTION: Write down the error information displayed on the console and
call your Hewlett-Packard support contact.
20 MESSAGE: Could not create or bind with the driver.
CAUSE: (
Status
= C3
xx
00D8) The wrong path number is configured for
the installed PSI card.
ACTION: Use NMMGR to correct the Physical Path for the link.
CAUSE: (
Status
= CD
xx
00D5) The card for the configured path number
is bad.
ACTION: Use NMMGR or the configuration file critical summary to
check that the Physical Path configured for the link corresponds to a
good PSI card. To determine whether the PSI card is good, your
Hewlett-Packard support contact will have to run diagnostics on the
PSI.
CAUSE: (
Status
= DA
xx
00D5) No card is in the slot for the path number
configured for the link.
ACTION: Use NMMGR or the configuration file critical summary to
check the configured Physical Path for the link, and correct it if
necessary. Or, call your Hewlett-Packard support contact to install a
PSI card.
CAUSE: (
Status
= E0
xx
00D5) The bus converter is not configured.
ACTION: Your local Hewlett-Packard support contact will have to check
the bus converter configuration in SYSGEN and reconfigure it, if
necessary (for Series 950 only).
CAUSE: (
Status
= FA
xx
00D8) The I/O subsystem still has the card
configured and marked active.
ACTION: First, try shutting down the link. If the problem continues,
restart the system. If this does not correct the problem, write down the