MPE/iX Error Messages Manual Vol 2 (32650-90902)
Chapter 9 335
System Startup, Shutdown, and Configuration (cont)
"Nonclass" Errors
FA MESSAGE No message. System halts. (E)
CAUSE Floating-point high priority machine check.
ACTION Contact your Hewlett-Packard Support Representative.
FB MESSAGE No message. System halts. (E)
CAUSE Instruction parity error occurs.
ACTION Contact your Hewlett-Packard Support Representative.
NOTE
HPMC codes FC through FF are currently undefined. If more than one error
occurs, only the error with the smallest error code is displayed. For example,
if both errors F4 and F7 occur, only F4 is displayed.
Console Messages for Log File Errors
Log file errors are reported in one of the following messages. Refer to Table 9-1. on page
335 for a summary of log file error numbers, their meaning, and whether they are
recoverable or irrecoverable errors.
LOG FILE NUMBER xxxx ERROR #nn. LOGGING STOPPED indicates that an irrecoverable
error occurred. System logging is disabled until the next system startup.
LOG FILE NUMBER xxxx ERROR #nn. LOGGING SUSPENDED indicates that a recoverable
error occurred. A recoverable error temporarily suspends logging until the RESUMELOG
command is issued.
Table 9-1. Log File Errors
ERROR NO. ERROR RECOVERABLE?
1 Input/output error in accessing the system disk. No
2 Input/output error in accessing disk log file. No
21 data parity error. No
26 Transmission error. No
27 Input/output timeout. No
28 data overrun. No
29 SIO failure. No
30 Unit failure. No
46 Insufficient disk space to create log file. Yes
Table 9-2. Log File Errors (Continued)
ERROR
NO.
ERROR RECOVERABLE?
47 Input/output error on file label. No