MPE/iX Error Messages Manual Vol 2 (32650-90879)
Chapter 8 287
System Startup, Shutdown, and Configuration
Class Errors
Class Error 2
Class error 2 is composed of translation look-aside buffer (TLB) and cache failures. These
two types of errors are coded 23xx and 27xx.
Translation Look-Aside Buffer (TLB) Failure
translation look-aside buffer messages take the form:
26xx
where:
xx = detailed error number.
00 MESSAGE No message. System halts. (E)
CAUSE Undefined error occurred at the start of the test of this
board.
ACTION Contact your Hewlett-Packard Support Representative.
01 MESSAGE No message. System halts. (E)
CAUSE Verification of the read and write operation on the space
registers through space ID fails.
ACTION Contact your Hewlett-Packard Support Representative.
02 MESSAGE No message. System halts. (E)
CAUSE Verification of the read and write operation on the space
registers through MTSP fails.
ACTION Contact your Hewlett-Packard Support Representative.
04 MESSAGE No message. System halts. (E)
CAUSE Verification of the read or write access to a page with
proper protection and access right fails. Second possible
cause of the error is the cache unit.
ACTION Contact your Hewlett-Packard Support Representative.
05 MESSAGE No message. System halts. (E)
CAUSE Verification of the write disable bit operation fails. Second
possible cause of the error is the cache unit.
ACTION Contact your Hewlett-Packard Support Representative.
06 MESSAGE No message. System halts. (E)
CAUSE Verification of the public access operation fails. Second
possible cause of the error is the cache unit.
ACTION Contact your Hewlett-Packard Support Representative.
07 MESSAGE No message. System halts. (E)
CAUSE Verification of the PSW P Bit operation fails. Second