MPE/iX Error Messages Manual Vol 1 (32650-90878)

Chapter 3 313
Command Interpreter
(CIERR) 1901-12256
TIME along with the ;NOW or ;GRADUAL option.
11706 MESSAGE CORRECTION must be the only parameter. (CIERR
11706)
CAUSE The SETCLOCK command's CORRECTION parameter
was provided while also including at least one other
parameter.
ACTION Issue the SETCLOCK command using CORRECTION as
the only parameter.
11707 MESSAGE TIMEZONE must be the only parameter. (CIERR
11707)
CAUSE The SETCLOCK command's TIMEZONE parameter was
provided while also including at least one other parameter.
ACTION Issue the SETCLOCK command using TIMEZONE as the
only parameter.
11708 MESSAGE CANCEL must be the only option or parameter.
(CIERR 11708)
CAUSE The SETCLOCK command's ;CANCEL option was
provided while also including at least one other parameter.
ACTION Issue the SETCLOCK command using ;CANCEL as the
only option or parameter.
11709 MESSAGE The DATE parameter has an incorrect format.
Expected mm/dd/yyyy. (CIERR 11709)
CAUSE The SETCLOCK command's DATE parameter did not
have valid numeric values for month, day and year.
ACTION Provide the DATE format in the format mm/dd/yyyy or
mm/dd/yy.
11710 MESSAGE The specified system time is too early.
(CIERR 11710)
CAUSE SETCLOCK was issued with a system time before
January 1, 1970 at 12:10 a.m. The system will not function
properly with a system time set before this value.
ACTION Issue the SETCLOCK with a DATE and TIME after
January 1, 1970 at 12:10 a.m.
11711 MESSAGE The specified DATE is out of range. (CIERR
11711)
CAUSE At least one of the numeric values for month, day, or year
were beyond the range one would expect for a month, day,
or year.
ACTION Issue the SETCLOCK command with a month in the
range 1 through 12, a day in the range appropriate for that
month, and a year between 1970 and 2027.