HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)
Appendix H
Error Messages and Warnings
Stage/iX Messages (STAGEMAN)
382
Stage/iX Messages (STAGEMAN)
This section lists the Stage/iX Error Messages, cause and action.
1001 Message Unable to execute USE file “name”.
(STAGEMAN 1001)
Cause STAGEMAN was unable to open and/or execute the file that the user
specified for the USE command.
Action Check the file system error message associated with the command, and
take the appropriate action.
1002 Message Missing required parameter in command. (STAGEMAN 1002)
Cause A required parameter for the command was not supplied.
Action Re-enter the command including the parameter. Do a HELP on the
command if necessary.
1003 Message Length of parameter exceeds maximum allowed. (STAGEMAN 1003)
Cause The string supplied for the parameter exceeded the maximum allowed
length of the parameter.
Action Do a HELP on the command to determine the maximum length of the
parameter, then re-enter the command.
1004 Message Invalid option. (STAGEMAN 1004)
Cause An option was specified that is not allowed for this user.
Action Re-enter the command without the option.
1005 Message Invalid parameter. (STAGEMAN 1005)
Cause An invalid parameter was specified.
Action Re-enter the command without the parameter.
1006 Message Empty string not allowed for this parameter. (STAGEMAN 1006)
Cause An empty string was found in a parameter where an empty string is not
allowed.
Action Re-enter the command with a valid string.
1007 Message Value of this parameter must be between 0 and 65535. (STAGEMAN
1007)
Cause An integer value outside of the allowable range was provided for this
parameter.
Action Re-enter the command with a value for the parameter between 0 and
65535.
1008 Message Illegal value. (STAGEMAN 1008)
Cause An unexpected and inappropriate value was supplied for this parameter.
Re-enter the command with an appropriate value for the parameter. Do a
HELP on the command to determine appropriate values if necessary.
1009 Message 1009 not used.