HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)

Appendix H
Error Messages and Warnings
Installer Error Messages (INSTERR)
376
Action Print the file to the screen. Each record should be a maximum of 80
bytes as defined in the CAUSE text. Check the file for unprintable
characters.
Using any editor, correct the file format.
Run the installer again.
Contact the Response Center for further assistance.
255 Message HPINSTAL failed. The CD-VERSION of OS is lower than system’s
BASE-VERSION. You cannot continue with installation (INSTERR
#255)
Cause The system OS version is newer than the CS OS version. HPINSTAL
allows CSLT creation under this condition only for remote systems.
Action Use HPINSTAL to create CSLT for local systems with only newer versions
OS CDs.
256 Message HPCIGETVAR failed in create CSLT (INSTERR #256)
Cause The installer issued the HPCIGETVAR intrinsic and failed. The status
returned for this message is displayed before this message.
Action Check the error message from the HPCIGETVAR intrinsic and based on
the status value displayed, take corrective action.
Run the installer again.
Contact Response Center if further assistance is required.