HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)

Appendix H
Error Messages and Warnings
Installer Error Messages (INSTERR)
373
Out of disk space - There are two methods for obtaining additional
disk space:
Use the ALTERVOL command in VOLUTIL to set the
permanent and transient space allocation assignments to
100% on all system volumes except LDEV 1.
Store user files to tape and then purge them. Restore the files
from tape at the end of the installation.
Transmission errors - Clean tape heads and check for hardware
errors.
Corrupt files - Manually RESTORE the corrupt files from the
CSLT/STORE tape. If successful, this indicates there were
transmission errors.
Take appropriate corrective measures, and run AUTOINST again.
Contact your Response Center if further assistance is required.
237 Message PowerPatch Release VUF is older than Subsys Release
VUF (INSTERR #237)
Cause The PowerPatch tape being installed is older than the last Powerpatch
tape installed on the system.
Action Print the file HPSWINFO.PUB.SYS and refer to line 4 of the file to
determine the V.U.F. of the SUBSYS currently installed on the system.
Refer to the accompanying READ BEFORE INSTALLING to
determine the SUBSYS releases supported by this PowerPatch tape.
Get a newer PowerPatch tape.
Contact your Response Center if further assistance is required.
238 Message Unable to open the AUTOINST message catalog (INSTERR #238)
Cause Either the AUTOINST catalog, AICAT000.INSTALL.SYS is missing or it
is not a valid catalog.
Action Ensure that the file AICAT000.INSTALL.SYS exists on the system.
If it does not and you are installing a PowerPatch tape, RESTORE
AUTOINST and AICAT000 from the PowerPatch tape. If you are
not installing PowerPatch, UPDATE with the SLT provided by HP,
and ensure that the file exists after the UPDATE.
If the file does exist, do a LISTF,2 of the file and ensure the CODE
is MGCAT.
Run AUTOINST again.
Contact your Response Center if further assistance is required.
239 Message Invalid Catalog AICAT000 in the INSTALL.SYS group.
The Catalog VUF could not be recovered (INSTERR #239)
Cause The catalog, AICAT000, is missing its VUF.