HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)
Appendix H
Error Messages and Warnings
Installer Error Messages (INSTERR)
366
Cause Setting the IODFDATA.PUB.SYS file equation required by the installer
and SYSGEN failed.
Action •The FILE Command Table is possibly full.
• Check if any further file commands can be entered with the FILE
command.
• RESET any USER file equations.
• Take appropriate corrective measures and run the installer again. The
installer will reissue any needed file equations.
• Contact the Response Center if further assistance is required.
198 Message Error resetting STORECAT.PUB.SYS file equation. (INSTERR
#198)
Cause The installer encountered an error resetting the file equation:
STORECAT.PUB.SYS
Action • Document any error message text prior to the error.
• RESET STORECAT.PUB.SYS
• Run the installer again.
199 Message 199 Not used
200 Message Failed to retrieve the OS build ID. (INSTERR #200)
Cause The installer failed to access the MPE/iX Operating System and Release
IDs of your system.
Action • Log on as MANAGER.SYS,INSTALL to your MPE/iX environment.
• Rerun the tool.
• Contact the Response Center if further assistance is required.
201 Message Your system is currently running software newer than
the release for which the CSLT was created. If you want to
continue,
match the build version of your system to the one reflected in
the
file TARGVUF.PUB.SYS. (INSTERR #201)
Cause Your system has been UPDATED with a newer MPE/iX release than the
one for which this CSLT/SOTRE tape was created.
Action • If your wish to backdate your system to the MPE/iX release contained
on the CSLT/STORE tape, follow the instructions outlined in chapter
entitled Backdating Your System of this manual.
• Contact the Response Center if further assistance is required.
202 Message The build of your system suggests that you did not
update from the CSLT before invoking HPINSTAL. Please refer to
the
installation manual. (INSTERR #202)
Cause HPINSTAL fails when an attempt is made to complete the update of a
system by invoking HPINSTAL a second time prior to UPDATing the
system with the combined CSLT/STORE tape created by HPINSTAL