HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)
Appendix H
Error Messages and Warnings
Installer Error Messages (INSTERR)
345
Action •FILE Command Table is possibly full. Do a LISTEQ command to
determine which USER file equations can be RESET. RESET any
USER file equations.
• Take appropriate corrective measures and run the installer again. The
installer will reissue any needed file equations.
• Contact the Response Center if further assistance is required.
91 Message Error while issuing file equation for the SL library.
(INSTERR #91)
Cause The installer attempted to issue the file equation:
:FILE SL.PUB.SYS=SL
(SL being in the local group INSTALL.SYS), prior to calling SYSGEN to
create the CSLT.
Action •FILE Command Table is possibly full. Do a LISTEQ command to
determine which USER file equations can be RESET. RESET any
USER file equations.
• Take appropriate corrective measures and run the installer again. The
installer will reissue any needed file equations.
• Contact the Response Center if further assistance is required.
92 Message Error while issuing file equation for the START IMAGE.
(INSTERR #92)
Cause The installer attempted to issue the file equation:
:FILE START.MPEXL.SYS=START
(START being in the local group INSTALL.SYS), prior to calling SYSGEN
to create the CSLT.
Action •FILE Command Table is possibly full. Do a LISTEQ command to
determine which USER file equations can be RESET. RESET any
USER file equations.
• Take appropriate corrective measures and run the installer again. The
installer will reissue any needed file equations.
• Contact the Response Center if further assistance is required.
93 Message Error while issuing file equation for SYSGTAPE. (INSTERR #93)
Cause The installer attempted to issue the file equation:
FILE SYSGTAPE;DEV= XXX
Where XXX is the LDEV number chosen at the start of the installation, as
the LDEV number where SYSGEN would create the CSLT.
Action •FILE Command Table is possibly full. Do a LISTEQ command to
determine which USER file equations can be RESET. RESET any
USER file equations.
• Take appropriate corrective measures and run the installer again. The
installer will reissue any needed file equations.
• Contact the Response Center if further assistance is required.
94 Message The current INSTALL file is blank or nil. (INSTERR #94)