HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)

Appendix H
Error Messages and Warnings
Installer Error Messages (INSTERR)
339
Store user files to tape and them purge them. Restore the files
from tape at the end of the installation.
Take appropriate corrective measures and run the installer again.
Contact the Response Center if further assistance is required.
69 Message Copy of SPLINTR.PUB.SYS to SPLINTR.INSTALL.SYS failed.
(INSTERR #69)
Cause The installer was attempting to copy SPLINTR.PUB.SYS to
SPLINTR.INSTALL.SYS.
Action Examine file SPLINTR.INSTALL.SYS for accessors other than the
installer.
If file is being accessed, free up file.
Check for free disk space to copy file, and if needed free up disk space.
There are two methods for obtaining additional disk space:
Use the ALTERVOL command in VOLUTIL to set the permanent
and transient space allocation assignments to 100% on all system
volumes except LDEV 1.
Store user files to tape and them purge them. Restore the files
from tape at the end of the installation.
Take appropriate corrective measures and run the installer again.
Contact the Response Center if further assistance is required.
70 Message A call to the LINKEDITOR by the installer failed. (INSTERR
#70)
Cause The link editor variables LKEDSTAT and/or LKEDCMD were checked
after a call to the link editor by the installer. The variables were found to
contain error values.
Action Record the error messages preceding this message.
Print file AUTOLOG.INSTALL.SYS to view detailed error from link
editor.
Check error message cause and action in the HP Link
Editor/iX Reference Manual.
Take appropriate corrective measures and run the installer again.
Contact the Response Center if further assistance is required.
71 Message The installer failed to purge TEMPNL when patching
the OS SOM. (INSTERR #71)
Cause The installer was attempting to purge an old work nl, TEMPNL.INSTALL
used when patching the OS SOM.
Action Examine file TEMPNL.INSTALL.SYS for accessors.
If accessors, free up file.
Take appropriate corrective measures and run the installer again.
Contact the Response Center if further assistance is required.