HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)
Appendix H
Error Messages and Warnings
Installer Error Messages (INSTERR)
336
• Check if any further file commands can be entered with the FILE
command.
• RESET any USER file equations.
• Take appropriate corrective measures and run the installer again.
• Contact the Response Center if further assistance is required. The
installer will reissue any needed file equations.
56 Message Setting file equation SYSINTRN failed. (INSTERR #56)
Cause Setting the SYSINTRN file equation required by the NM intrinsic patcher
ABLDINTX.INSTALL.SYS failed.
Action •FILE Command Table is possibly full.
• Check if any further file commands can be entered with the FILE
command.
• RESET any USER file equations.
• Take appropriate corrective measures and run the installer again. The
installer will reissue any needed file equations.
• Contact the Response Center if further assistance is required.
57 Message Error trying to RUN ABLDINTX.INSTALL.SYS. (INSTERR #57)
Cause Could not create ABLDINTX process. Createprocess error: status
Action • The CREATEPROCESS intrinsic returned an error status when
attempting to execute ABLDINTX.INSTALL.SYS.
• Check the returned CREATEPROCESS error in the MPE/iX
Intrinsics Reference Manual.
• Print file AUTOLOG.INSTALL.SYS to check for further errors.
• If ABLDINTX.INSTALL.SYS does not exist, restore ABLDINTX.@.@
from the Powerpatch tape.
• Ensure INSTALL group has sufficient capabilities. (need CAP=PH).
• Take appropriate corrective measures and run the installer again.
• Contact the Response Center if further assistance is required.
58 Message Error trying to RUN BUILDINT.PUB.SYS. (INSTERR #58)
Cause Could not create BUILDINT process. Createprocess error: status
Action • The CREATEPROCESS intrinsic returned an error status when
attempting to execute BUILDINT.PUB.SYS.
• Check the returned CREATEPROCESS error in the MPE/iX
Intrinsics Reference Manual.
• Print file AUTOLOG.INSTALL.SYS to check for further errors.
• Ensure group for BUILDINT has sufficient capabilities. (need
CAP=PH).
• Take appropriate corrective measures and run the installer again.
• Contact the Response Center if further assistance is required.