HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)

Appendix H
Error Messages and Warnings
SETUP Error Messages (SETERR)
316
Reset the files for which you no longer need file equations. (If no file
equations are needed, do a RESET @.)
Execute SETINIT.INSTALL.
Contact the Response Center if further assistance is required.
23 Message Unable to set file equation for the file HICAT000.INSTALL.
Setup
will terminate. Follow the instructions in your installation
manual
to continue. (SETERR #23)
Cause SETUP.INSTUTIL forces the file HICAT000.INSTALL onto LDEV 1 by
setting a file equations prior to copying the file from compact disk.
However, SETUP.INSTUTIL failed when attempting to set the file
equation.
Action Do a LISTEQ to determine the file equations that have been set.
Reset the files for which you no longer need file equations. (If no file
equations are needed, do a RESET @.)
Execute SETINIT.INSTALL.
Contact the Response Center if further assistance is required.
24 Message Unable to set file equation for the file PEXL.INSTALL. SETUP
will terminate. Follow the instructions in your installation
manual
to continue. (SETERR #24)
Cause SETUP.INSTUTIL forces the file PEXL.INSTALL onto LDEV 1 by setting
a file equations prior to copying the file from compact disk. However,
SETUP.INSTUTIL failed when attempting to set the file equation.
Action Do a LISTEQ to determine the file equations that have been set.
Reset the files for which you no longer need file equations. (If no file
equations are needed, do a RESET @.)
Execute SETINIT.INSTALL.
Contact the Response Center if further assistance is required.
25 Message PURGEGROUP command failed when attempting to purge the
group PUB. curr_acct. SETUP will terminate. Follow the
instructions
in your installation manual to continue. (SETERR #25)
Cause SETUP.INSTUTIL uses the data file GRPNAMES.CD vuuff .SYS to
determine the accounting structure on the compact disk set. SETUP.
INSTUTIL must purge the group PUB. curracct from the system domain
prior to binding to it on the CD.
Action Ensure the group is not busy.
Execute SETINIT.INSTALL.
Contact the Response Center if further assistance is required.