HP e3000 MPE/iX System Software Maintenance Manual (Release C.75.00) (30216-90344)

Chapter 5
Modifying Your System
5.13 Applying the CSLT Modification
129
5.13 Applying the CSLT Modification
This section is for applying the Customized System Load Tape (CSLT) created by AUTOINST, HPINSTAL, or
HP Patch/iX. For Manage Patch tasks, this is the CSLT/STORE tape (not a STORE only tape). For
re-installations, it is the CSLT created most recently in SYSGEN.
To apply the CSLT tape:
1. From the console, mount reel one of the CSLT tape on the tape drive, and put the tape drive online.
Wait until a message displays on the system console verifying that the tape is mounted.
2. If you are using the AutoRestart product and AUTOBOOT is enabled, turn it off so the system won't
automatically reboot from the primary boot path.
:RUN BLDDUMP.HP36375.TELESUP
blddump>AUTOBOOT OFF
blddump>EXIT
3. Shutdown the system.
CTRL-A
=SHUTDOWN
4. Reset the system after the last shutdown message (SHUT6).
a. If you have an HP e3000 Series 99x, connect to the service processor before you can restart the
system. Type the following:
CTRL-B
CM>SP
SP>RS
Enter Y to HARD BOOT the computer system.
Do not respond to the question:
Press any key within 10 seconds to cancel boot with this
configuration.
There are 5 to 10 minutes of system activity, then the Processor Dependent Code (PDC) screen
displays.
b. For HP e3000 N-Class, A-Class
CTRL-B
Service Processor login:
Service Processor password:
If you get the following prompt, then enter the characters ‘Ctrl-E c fto gain write access to the GSP.
[Read only - use ^Ecf for console write access.]
GSP>RS
c. Enter the following commands to reset the system:
CTRL-B
CM>RS
d. If the system does not respond to the CTRL-B entry within ten seconds, press the reset button, key
switch, or on/off switch as appropriate for your system. The system will halt, and then restart
automatically.
e. Enter Y to confirm restarting the system.