HP e3000 MPE/iX Release 7.0 System Software Maintenance Manual (30216-90317)

410 AppendixH
Error Messages and Warnings
Installer Error Messages (INSTERR)
corrupt.
Action Document any error message text prior to the error.
Use SHOWVAR MPE_TARG_VUF to check the status
of the variable.
Print the INITCIVR.INSTALL. There should be a line
with a SETVAR command for the indicated variable. If
the line does exist, execute INITCIVR and run
HPINSTAL again.
If INITCIVR.INSTALL.SYS does not exist or does not
contain the SETVAR command for the listed CI variable,
VSCLOSE both CD-ROM volumes and follow the setup
procedures in the HPINSTAL manual. Run HPINSTAL
from the start.
188 Message Encountered an error building the file TARGVUF.
(INSTERR #188)
Cause The installer was attempting to build the file TARGVUF.
Action Document any error message text prior to the error.
If old TARGVUF exists, purge it.
Check for enough free disk space to build files. There
are two methods for obtaining additional disk space:
Use the ALTERVOL command in VOLUTIL to set the
permanent and transient space allocation
assignments to 100% on all system volumes except
LDEV 1.
Store user files to tape and them purge them.
Restore the files from tape at the end of the
installation.
Take appropriate corrective measures and run the
installer again.
Contact the Response Center if further assistance is
required.
189 Message Error encountered purging the file SYSGLOG.
(INSTERR #189)
Cause The installer was attempting to purge the log file
SYSGLOG.
Action Document any error message text prior to the error.
Examine file for accessors other than the installer.
If file is being accessed, free up file.
Take appropriate corrective measures and run the
installer again.