Advanced Forms Design
Processing Specifications For Configuration
Processing Specifications For Configuration
You can use the processing specifications for configuration to specify local editing to be
done on the HP 2394A and HP 2624A/B terminal, and to specify the input device and
prompting lights for use on the data capture devices.
These statements may only be used in the configuration phase of field processing, and
must have the CONFIG heading in the processing specification area of the Field Menu.
NOTE
VPLUS edit processing specifications and terminal edit processing
statements are separate and are not checked for compatibility. There will be
no check to see that the designer has specified a terminal local edit
(DEC_TYPE_EUR, DEC_TYPE_US) in the configuration phase which is
consistent with the language-dependent decimal indicator for the native
language specified in the forms file. For more information on Native
Language Support see Section 8.