Configuring Systems for Terminals, Printers, and Other Serial Devices (32022-90057)

Terminal and Printer Profiles
Terminal Switching Configuration Screen
Chapter 7
119
field on Terminal Profile screen must be enabled. Field is valid for
modem ports only (“Modem behavior” field on Terminal Profile screen
must be set to 1, 2, or 3).
Save port config in binary? Specifies whether the port configuration parameters
data length and parity settings will be maintained when binary mode
is selected. If set to Y, then the port configuration remains unchanged
when binary mode is selected. If set to N, then the data length is set to
8 and parity is set to none when binary mode is selected. The default is
N. Supported on DTC 16iX/DTC 16MX and DTC 72MX only.
Default destination Specifies the default system to which the terminal will connect.
This destination will be used if the c[onnect] command is entered
without a system name at the DTC prompt or if automatic connection
is enabled. Field must be completed if switching is disabled or if
automatic connection is enabled. Field can be a node name in the
format name.domain.organization or an IP address in the format
xxx.xxx.xxx.xxx. Default is the entry in the field “Local HP e3000
node name” on the Main screen.
Initialization string Optional field that specifies the string that will be sent to the
attached device under one of the following circumstances:
After resetting a port.
After closing a session on the host and returning to the DTC user
interface.
After entering the escape character during a system session and
returning to the DTC user interface.
After establishing a connection to the DTC user interface for
modem connections when all modem signals are up.
Field is case-sensitive and can be up to 16 characters, including special characters and
escape-code sequences in the format ˆchar.