Communicator e3000 MPE/iX Release 7.5 (Software Release C.75.00) (30216-90336)

Chapter 4
Fibre Channel Device and Adapter Support on HP e 3000 Systems
HP SureStore Virtual Array 7100 on the HP e3000
67
HP SureStore Virtual Array 7100 on the HP e3000
By Walter McCullough Commercial Systems Division
Product Brief
The HP SureStore Virtual Array 7100 is HPs newest mid-range fibre channel disk storage system that is the
replacement for the 12H AutoRAID. The VA7100 holds from 4 to 15 disk drives. The array has scalable
capacities from 72 GB to 270 GB (211 GB usable) with all 18-GB disk drives and from 144 GB to 540 GB (428
GB usable) with all 36-GB disk drives and from 292 GB to 1.1 TB with 73-GB disk drives. Capacities and
spindle speeds can also be mixed.
For added reliability and redundancy the array should be ordered in a dual controller configuration. Each
controller has two DIMM slots available to hold NVRAM. The NVRAM is used for read/write caching and for
storing array memory maps.
The VA7100 can operate in either RAID 1+0 mode or AutoRAID mode, which eliminates the requirement for
the system administrator to understand and configure RAID levels. AutoRAID dynamically adapts to the
systems workload, optimizing performance and cost. Users will find configuration significantly easier than
other array products, since RAID levels dont need to be configured or managed. The VA7100 supports one
redundancy group, and all drives belong to that group. Using Virtual Storage Array (VSA) technology, when
configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and
mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data. RAID 5DP
provides superior data redundancy by protecting against the simultaneous failure of two member disks by
using independent error correction schemes.
Site, Software and Hardware Requirements
Device installation and support is to be provided by HP. For detailed information on the support and
configuration of the Virtual Array 7100, field support personnel should consult the updated versions of the
following documents:
HP SureStore Virtual Array 7100 Disk Array Quick Start Guide
http://www.hp.com/products1/storage/disk_arrays/midrange/va7100/infolibrary/index.html
. Then click on technical support
HP SureStore Command View SDM http://www.hp.com/products1/storage/disk_arrays/modular/
NOTE The Command View SDM software is currently required on an NT PC or HP-UX workstation.
VA7100 Configuration Requirements
Firmware version HP13.
Port behavior set to HPUX.
Port Topology should be set to Private Loop.
Use controller 1 as the primary access port.
Rebuild Priority should be set to Low.
Logical Unit Number (LUN) (0) must be configured for Command View SDM to work properly.