Communicator e3000 MPE/iX Release 7.0 (C.70.00) (30216-90312)
Chapter 5 79
Technical Articles
PCS/iX (SCOPE) Enhanced with Expanded Limits
PCS/iX (SCOPE) Enhanced with Expanded Limits
By James Overman
Computer Systems Division
The Performance Collection Software (PCS/iX) product (also known as SCOPE/iX) HP
B1794B for MPE/iX has been enhanced to support larger numbers of disks, CPU's, and
other system resources with the version B.13.52 shipped in MPE/iX 7.0. This PCS version
produces modified format Raw Logfiles (version D of LOGGLOB.SCOPE.SYS, etc.) and
also modifies the format of Extracted RX Logfiles that are analyzed by the PerfView
products. HP Perfview and Measureware products are now known as HP Vantage Point
Performance Manager and Agent, respectively.
This new version of PCS/iX supports the increased HP e3000 MPE/iX limits of 511 disks,
15 processors, and 16Gbyte memory sizes. Also, the data fields have been tweaked to
correctly process the much larger possible sizes of disk storage, number of pins, and other
system resources that have grown along with the more powerful HP e3000s. The
expanded and modified data items required the update of the MeasureWare Agent portion
of the HP PerfView software [HP Vantage Point Performance AGENT]. Older versions of
HP MeasureWare and the obsolete HP LaserRX software will not process the new
Extracted RX logfiles.
New releases of HP MeasureWare Agent that understand the new MPE/iX 7.0 Extracted
RX logfiles are available. Those releases should be acquired by customers through the
usual HP Support Channels. Generally, a Patch for your platform may be requested from
HP in the normal manner (download from the IT Resource Center, or request from the
Response Center).
Immediately after updating or installing PCS/iX B.13.52.03, it will be necessary to use the
UTILITY.SCOPE.SYS program to CONVERT the previous Raw Logfile formats (B or C) to
the new D version, if not previously converted. This one-time conversion should require
less than five minutes for even the largest Raw Logfiles. This conversion step must be
performed prior to attempting to restart the SCOPEJOB that collects the PCS data.
The Extracted RX logfiles will be automatically created and modified when they are
referenced by the EXTRACT.SCOPE.SYS program. If any problems are experienced with
appending to previous RX logfiles, the RX output file may be purged and re-extracted in its
entirety. Note that when extracting a period file (month, week, year), the previous period
file is examined and updated if needed, before the current period file is addressed