8-port Serial PCI ACC Multiplexer Installation & Service Guide (30291-90508)
Chapter 2 23
Hardware Installation
Installing the 8-Port PCI ACC Multiplexer
2. Attach the plate to the rack using appropriately-sized
machine-metal screws for your rack.
3. Place one interchange panel against the back plane of the mounting
plate. Mount it to the plate, using the M3x10 Torx screws provided
with the plate.
4. To mount another interchange panel to this same plate, repeat the
preceding step. Note that you can position the plate in a different
direction from the first one, as shown in Figure 2-2.
Figure 2-2 Rack Mounting Plate In Use
Connect the MUX to (one of) the Interchange Panel(s)
CAUTION Before connecting the MUX card cable to the interchange panel, be sure
that the power to the computer is off. Otherwise, serious equipment
damage may occur.
1. Connect one end of the supplied cable to the connector on the MUX
card and the other end to the interchange panel.
2. Apply power and reboot the computer.
3. After power is applied, check the Self Test LED indicator at the
bulkhead of the MUX card, refer to Figure 2-3.
Figure 2-3 MUX Card Bulkhead with Self Test Indicator
J0J1J2J3
P1
J4J5J6J7
P2
Z7322A
V.35 INTERCHANGE PANEL
J0J1J2J3
P1
J4J5J6J7
P2
Z7322A
V.35 INTERCHANGE PANEL
Self
Test
Z7340A