Using the Node Management Services (NMS) Utilities (32022-90053)

234 AppendixA
NMS Error Messages
NMGR Error and Warning Messages
MESSAGE: Aux NCONF file not opened. (NMGRERR 204)
NMGRERR 204 CAUSE: This is an internal guided configuration error caused when
data is copied from the auxiliary file to the user file and the auxiliary
file was not opened.
ACTION: See “Submitting an SR” at the beginning of this appendix.
MESSAGE: Aux file does not contain specified path. (NMGRERR 205)
NMGRERR 205 CAUSE: This is a guided configuration error caused when NMMGRCAT
specifies a path in the auxiliary file that does not exist.
ACTION: Copy NMAUX1.PUB.SYS from back-up tape, and run
NMAINT.PUB.SYS to make sure that the version of NMAUX1 is the
same as the version of NMMGR.
MESSAGE: Path to subtree in user file does not exist.
(NMGRERR 206)
NMGRERR 206 CAUSE: This problem could be caused by a corrupt file or by an old
configuration file that needs to be updated.
ACTION: Run NMMGRVER.PUB.SYS. If needed, restore a known good
configuration file from a back-up tape, or create a new configuration file
with NMMGR.
MESSAGE: Internal error; Guided token overflow. (NMGRERR 207)
NMGRERR 207 CAUSE: This is an internal guided configuration error.
ACTION: Restore NMMGRCAT.PUB.SYS from a back-up tape. If this fails
see “Submitting an SR” at the beginning of this appendix.
MESSAGE: Unexpected Guided Config error. (NMGRERR 208)
NMGRERR 208 CAUSE: An unexpected or internal guided configuration error occurred.
ACTION: Type the “ERROR” command after this message is displayed
for clarification of the error(s). A PC value is specified at the end of this
error message. If you are unable to include the value problem, submit
an SR. See “Submitting an SR” at the beginning of this appendix. Be
sure to include the value of the PC with the SR.
MESSAGE: Cannot Stop Guided Configuration. (NMGRERR 209)
NMGRERR 209 CAUSE: The STOP command is allowed only on screens which contain a
“path.” This is most likely to occur when the user types the command
“STOP” on the errors screen during guided configuration.
ACTION: Move to a screen which contains a “path” at the top of the
menu and retype the stop command.
MESSAGE: Cannot perform NEXT function. (NMGRERR 211)
NMGRERR 211 CAUSE: This error occurs when the user attempts to use the NEXT
command when no selection screen has been encountered.