TurboIMAGE/XL Database Management System Reference Manual MPE/iX V6.5 (30391-90011)

Appendix A 621
Error Messages
Utility Error Messages
Utility Unconditional Error Messages
MESSAGE AUTOMATIC MASTER IS FULL ON PATH
#n
MEANING DBLOAD is unable to load a detail entry because the automatic master set
associated with path n of the detail set is full.
ACTION Re-create the root file with a larger capacity for automatic master. Rerun
the necessary utilities.
MESSAGE ***BAD DATABASE***
MEANING This message is issued by DBSTORE, DBRESTOR, and DBUNLOAD. It means
the database is flagged "bad" because of a known structural error due to an
abnormal termination or to a system failure during DBLOAD or some other
"deferred output" operation. The current operation (DBSTORE,
DBRESTOR, DBUNLOAD) continues to function normally. DBLOAD
additionally prints the message "SERIAL UNLOAD FOLLOWS" and
automatically operates in serial mode. The database on disk retains its
"bad" flag and cannot be accessed through DBOPEN.
ACTION The database is not usable in its current state. Purge it and restore a
backup copy, or erase it and then load a tape written by DBUNLOAD or
another external copy of the data.
MESSAGE BROKEN FILE EQUATION CHAIN FOR TAPE FILE
MEANING Issued by DBSTORE if, in a chain of file equations, the actual device
designator cannot be found.
ACTION Check your MPE FILE commands and reenter them correctly before
running DBSTORE.
MESSAGE CANNOT GET EXTRA DATA SEGMENT NECESSARY FOR RESTORE
OPERATION
MEANING DBRESTOR was unable to get the extra data segment it needed for the
buffers used in the restore operation.
ACTION Wait until system resources are available and then try again.
MESSAGE CANNOT OPEN TERMINAL, TERMINATING
MEANING DBUTIL is unable to access the terminal.
ACTION Call HP systems engineer.