TurboIMAGE/XL Database Management System Reference Manual MPE/iX V6.5 (30391-90011)

612 AppendixA
Error Messages
Utility Error Messages
MESSAGE MUSTRECOVER & ROLLBACK MUST BE DISABLED BEFORE DISABLING
LOGGING
MEANING Logging cannot be disabled if either MUSTRECOVER or roll-back recovery is
active.
ACTION Disable both MUSTRECOVER and roll-back recovery before disabling
Logging.
MESSAGE NEGATIVE CURRENT RECORD NUMBER IN BACKSPACE REQUEST
MEANING Internal error.
ACTION Contact your database administrator.
MESSAGE NEGATIVE NUMBER OF BACKSPACES REQUESTED
MEANING Internal error.
ACTION Contact your database administrator.
MESSAGE NLS RELATED ERROR
MEANING An error was returned by NLS/3000 on a DBOPEN on the database.
ACTION Notify the database administrator.
MESSAGE NLINFO FAILURE
MEANING An error was returned by NLS/3000.
ACTION Notify database administrator.
MESSAGE NO DATABASE HAS BEEN SPECIFIED FOR RECOVERY
MEANING RUN command has been entered and no databases have been specified for
recovery.
ACTION Use the RECOVER command to specify database(s) or EXIT to terminate.
MESSAGE NO INDEXING PRODUCT CONFIGURED
MEANING This message is returned if you are not using third-party indexing (TPI)
and you attempted to disable the database for indexing. The message is
generated by the DBUTIL DISABLE database name FOR INDEXING
command when the database is not configured for third-party indexing.
ACTION Disregard the message if your database is not configured for third- party
indexing.