TurboIMAGE/XL Database Management System Reference Manual MPE/iX V6.5 (30391-90011)

Chapter 5 227
TurboIMAGE/XL Library Procedures
DBPUT
Refer to appendix A for more information about these conditions.
Communications
Errors:
-102 DSWRITE failure.
-106 Remote 3000 data inconsistent.
-107 NS 3000 or DS 3000 system error.
Logging System
Failures:
-111 WRITELOG failure.
Exceptional
Conditions:
-193 DBU control block is full.
-196 DBB control block is full.
-212 Database corruption detected.
-264 XM write procedure returned 1030 or 1040.
-312 Internal error encountered while reading database block.
-314 Error while obtaining path information for set.
-322 Error returned by process list.
-332 Error in QLOCK table operation.
16 Data set full.
(In the following messages, dataset# and FSERR # will be
replaced by the actual number.)
DBPUT cannot expand dataset#: dataset at maximum capacity.
DBPUT dataset# incomplete expansion: File system error #.
DBPUT cannot expand dataset#: Out of disc space (FSERR #).
18 Broken chain; forward and backward pointers not consistent.
43 Duplicate key item value.
62 DBG control block is full.
63 DBG disabled; potential damage; only DBCLOSE allowed.
1
nn
Missing chain head for path number
nn
.
2
nn
Full chain for path number
nn
.
3
nn
Internal error.
4
nn
Full synonym chain.
Table 5-21. DBPUT Return Status Values