Standalone Logtool for MPE/iX
No units with status pending
>>>>>>>>>> Access Errors <<<<<<<<<<<\esc>
Drive is not ready for access
New target address is :
Vector address =
Cylinder = 0 Head = 0 Sector = 0
Block address = 0
=============================================================================
TUE, MAR 31, 1990 10:36 AM LOG0009.PUB.SYS SYSTEM (PIN 28)
I/O ERROR (NUMBER OF RECORDS = 1)
LDEV: 2
HARDWARE STATUS:
Status =
Unit = 0 Volume = 0
No units with status pending
>>>>>>>>>> Access Errors <<<<<<<<<<<\esc>
Received an address which exceeds device bounds
New target address is :
Vector address =
Cylinder = 0 Head = 0 Sector = 0
Block address = 0
=============================================================================
TYPE DESCRIPTION COUNT
====== ==================== ==========
111 I/O ERROR 45
====== ==================== ==========
LOGTOOL>
SUSPEND
The SUSPEND command returns control to the MPE/iX user interface. LOGTOOL is temporarily suspended and may be
resumed by typing EXIT
Syntax:
SUSPEND
Example:
LOGTOOL>suspend
LOGTOOL in SUSPEND - [Type EXIT to continue]
MPE_PROMPT> (any MPE/iX commands)
MPE_PROMPT> exit
LOGTOOL resuming from SUSPEND mode ...
LOGTOOL>
SWITCHLOG
The SWITCHLOG command causes a new system log file to be opened and the old one to be closed. The LOGTOOL
STATUS
command may be used to obtain the new log file name. To execute this command, the user must possess at
least diagnostic security level 1. {For MPE/iX, the display from the SHOWLOG command and SWITCHLOG command will
appear on the system console).
Syntax:
SWITCHLOG
Limitations: This command affects only the system log files. Examples:
LOGTOOL>switchlog