SNA NRJE Node Managers Guide (30292-90007)

Chapter 5 67
SNA NRJE Troubleshooting
Using NMDUMP for SNA NRJE
Intrinsic Trace Records Intrinsic trace records are type 1, and are
formatted according to two subtypes:
Subtype 0: workstation number
Subtype 1: wsid and number
SNA NRJE produces a subtype 1 intrinsic trace record for the first
intrinsic trace record in a trace file for a given workstation. (Any
continuation records for subtype 1 intrinsic trace records are also
subtype 1.) A subtype 1 trace record header shows the type of tracing,
the version ID, the workstation number (used to identify the
workstation within a trace file), the workstation ID (wsid), the user ID,
and the intrinsic number.
The intrinsic names and their corresponding numbers are shown below.
INTRINSIC NAME MODULE # INTRINSIC NAME MODULE #
NRJEQUEUE 1 NRJESTARTWS 9
NRJEALTER 2 NRJEWSINFO 10
NRJECANCEL 3 NRJEWRITER 11
NRJERDRFENCE 4 NRJELULIST 12
NRJEDRACCESS 5 NRJECONSOLE 13
NRJEJOBINFO 6 NRJETRACE 14
NRJESUBMIT 7 NRJELUSTATUS 15
NRJESTOPWS 8
This is an example of a subtype 1 intrinsic trace record header.
**********************************************************************
* Subsystem NRJE (2) Intrinsic tracing data *
* TUE, APR 3, 1984, 4:07 PM, TIMER= 58021.707 *
* *
* ------------------------- Info section ------------------------- *
* #: 0101 0000 0000 0000 0000 5232 3020 2020 *
* 2020 0001 4B45 5649 4E20 2020 4B4F 5242 *
* 2020 2020 4E52 4A45 2020 2020 000E *
* *
* Intrinsic tracing: Workstation header record (1/1) *
* Version : A.00.00.000 *
* Workstation : 1 , ID = R20 *
* User : MANAGER.SYS, NRJE *
* Intrinsic : 14 *
**********************************************************************