SNA NRJE Node Managers Guide (30292-90007)

44 Chapter3
SNA NRJE Configuration
Configuring SNA NRJE
Autostart
Enter Y if you want the LU to be automatically
initialized when the workstation is started up; N,
otherwise. You can override this at workstation startup
time. Note that you cannot enter a value in this field if
a value is not also entered in the corresponding LU
Name field.
Default: N
File
For display only. The name of the configuration file.
Once you have entered the data for all of the LUs, press
[f6] [Save Data].
After the information is processed, press
[f8]
[Prior Screen] until you get back to the NRJE
Configuration: Workstation Data screen. Then, if you
need to configure the virtual reader for the workstation,
press
[f2] (Go To READER).
Reader Data Screen
Once you have configured the LUs for the workstation, you should
configure the workstation’s virtual reader next. You do this on the
NRJE Configuration: Reader Data Screen. Select this screen by
pressing
[f2] (Go To READER) on the NRJE Configuration: Workstation
Data screen. (You can go directly to this screen from any screen by
typing @NRJE.
wsid
.READER in the command window and pressing
[ENTER].) NRJE spools submitted jobs to the virtual reader. If the
communications line to the host is down, NRJE holds jobs in the queue
until the line is active. NRJE then transmits the jobs according to their
position in the queue. You configure only one reader for each
workstation. This reader is an internal MPE spooling device and does
not correspond to readers configured at the host.