Read Before Installing MPE/iX PowerPatch 1 Based on Release 6.5 (30216-90319)
8 Chapter1
Information You Need Before Installing MPE/iX 6.5 PowerPatch 1
Process for Installing the ODILX77 Patch Bundle for MPE/iX 6.5
Process for Installing the ODILX77 Patch Bundle for
MPE/iX 6.5
Because of the nature of the patch bundle (the fix for Problem #3), you have to manually
shut down the diaglogd daemon before loading the patches, and manually start the
daemon afterwards. If you don't do this, the system may hang.
Before installing the patch, execute the "dsd diaglogd" command at the cstm prompt. (dsd
= daemonshutdown). After the deamon is shut down, execute the "exit" command at the
cstm prompt. Sample dialog:
:cstm
.
.
.
cstm> dsd diaglogd
-- Daemon Shutdown --
The daemon diaglogd will be aborted on the host
hpdst185.cup.hp.com.
Diaglogd Description:
OS Error Logging Daemon, logs information from the OS into log
files.
Are you sure you want to shutdown diaglogd?
Enter Cancel, Help, or OK: [Cancel]ok
cstm>exit
-- Exit the Support Tool Manager --
Are you sure you want to exit the Support Tool Manager?
Enter Cancel, Help, or OK: [OK] ok
:
After the patch has completed installation, restart the Support Tools Manager by entering
"cstm" at the MPE/iX system prompt. Because the diaglogd daemon has been shut down,
you will see some warning-type messages. Type CONTROL-Y to exit from the messages. At
the cstm prompt, type "ssu" (stmstartup) to start the diaglogd daemon. You can now use
cstm as you normally would. Sample dialog:
:cstm
.
.
.