NS3000/iX Error Messages Reference Manual (36923-90041)
Chapter 19 565
Logging Location Codes
X.25 Logging Location Codes
MESSAGE: Internal Error.
223 CLAS0002 CAUSE: Map_X25_Update failed on inbound connection establishment
(PARM = Status from Map_X25_Update).
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
224 CLAS0005 CAUSE: Map_find_best_device failed on outbound level 3
connection establishment Occasionally, this can be a normal event
indicating that the link between the system and the DTC went down
just after a connection request was received by the system. (PARM =
Status from Map_find_best_device).
ACTION: Verify that the link between the system and the DTC is up:
From the system, check for a non-zero LDEV in the NETCONTROL
STATUS;NI=x25niname> display. From OpenView DTC Manager,
check the host entries at the end of the X.25 level 3 status display. If the
link is up, try the connection again. If this message is logged
consistently, see Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
225 CLAS0002 CAUSE: X.25 tried to send a message to X25STAT but the call failed.
(PARM = status from send_msg).
ACTION: Try running X25STAT again. If this logging message is logged
consistently, see Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
226 CLAS0004 CAUSE: Link brought down with open connections. This is a result of a
Netcontrol Stop on this X.25 network. (PARM = Connections in use on
this link).
ACTION: None. This is an informative message.
MESSAGE: Internal Error.
228 CLAS0002 CAUSE: Link_ptr is nil. (PARM= link id).
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: Internal Error.
229 CLAS0002 CAUSE: BMGR_DELETE_POOL call failed while start sequence was
aborting. (PARM= status from call).
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: Internal Error.
230 CLAS0002 CAUSE: Unknown link for disconnect reply. (PARM= link id).
ACTION: See Appendix A, “Submitting an SR,” of this manual.