492 Chapter19
Logging Location Codes
Remote Link Manager Logging Location Codes
ACTION: Check status of X.25 protocol on DTC. Possible causes include
bad/disconnected cable between DTC and switch/X.25 network, or the
switch/X.25 network is down. When problem is corrected, HP 3000 will
display additional logging messages and the network will be usable.
MESSAGE: None
100 CLAS0002 CAUSE: Could not create the RLM’s Port Data Area (PARM =
'create_object' status). Available virtual space may have been
exhausted.
ACTION: Contact your Hewlett-Packard representative and/or see
Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
101 CLAS0002 CAUSE: Could not obtain plabel for NL.PUB.SYS procedure
'remote_link_manager.' Possible software installation problem
(PARM = status returned by 'hpgetsysplabel').
ACTION: Check the status of the DTC.
MESSAGE: None
102 CLAS0002 CAUSE: Could not create the port for the RLM server (PARM = status
returned from 'create_port').
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
103 CLAS0002 CAUSE: Could not create the port for the RLM server (PARM = status
returned from 'create_port').
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
104 CLAS0003 CAUSE: Could not open AFCP protocol module (PARM = status
returned from 'mcm_module_config').
ACTION: Check X.25 and DTS Link configuration. If no problem is
found, see Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
105 CLAS0001 CAUSE: Could not send message to the RLM server. (PARM = status
returned from 'send_msg').
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
106 CLAS0002 CAUSE: Could not obtain information on per process port (PARM =
status returned from 'port_info').
ACTION: See Appendix A, “Submitting an SR,” of this manual.