NS3000/iX Error Messages Reference Manual (36923-90041)

Chapter 19 453
Logging Location Codes
NFT Logging Location Codes
NFT Logging Location Codes
MESSAGE: None
1 CLAS0002 CAUSE: Attempt to open file NFCAT2 failed. Logging entry will also
contain a file system error.
ACTION: Act according to the file system error. For example, if the error
is “non-existent permanent file”, then the system manager should place
a copy of NFCAT2 in NET.SYS.
MESSAGE: None
10 CLAS0002 CAUSE: Attempt to open file NFTCAT2 failed. Logging entry will also
contain a file system error.
ACTION: Act according to the file system error. For example, if the error
is “non-existent permanent file”, then the system manager should place
a copy of NFTCAT2 in NET.SYS.
MESSAGE: None
6 CLAS0003 CAUSE: NFTCAT2 contains invalid configuration values.
ACTION: System manager should obtain a version of NFTCAT2 that has
valid configuration values and install it in NET.SYS. Another resource
is to change the configuration values in the existing NFTCAT2 file.
However, Hewlett-Packard does not recommend this procedure. If any
other internal errors (CLAS0000) are logged for the NFT module of the
Network Services subsystem, see Appendix A, “Submitting an SR,” of
this manual.
MESSAGE: None
10 CLAS0003 CAUSE: Incompatible version of NFTCAT2 installed.
ACTION: System manager should obtain correct version of NFTCAT2
and install it in NET.SYS.