NS3000/iX Error Messages Reference Manual (36923-90041)

416 Chapter19
Logging Location Codes
IP Logging Location Codes
IP Logging Location Codes
MESSAGE: None
101 CLAS0003 CAUSE: Received a port message containing an invalid function code
(PARM = complete function code).
ACTION: See Appendix A, “Submitting an SR,”of this manual.
MESSAGE: None
102 CLAS0004 CAUSE: Log IP port initiation (PARM = PDA ptr).
ACTION: Informative.
MESSAGE: None
103 CLAS0002 CAUSE: The length of the IP address alias list passed in an INFO
message exceeds the space allocated for the list in the IP port (PARM =
# of entries in the alias list).
ACTION: See Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
104 CLAS0006 CAUSE: Log IP statistics prior to port terminate (PARM unused).
ACTION: Informative.
MESSAGE: None
105 CLAS0004 CAUSE: Log IP port termination when a TERMINATE message is
received (PARM unused).
ACTION: Informative.
MESSAGE: None
106 CLAS0003 CAUSE: Received a Probe or Dial reply with an error status (PARM =
Probe/Dial reply status code in upper 16 bits; Probe/Dial ID in lower
16 bits).
ACTION: An occasional error may be tolerated. For persistent errors
see Appendix A, “Submitting an SR,” of this manual.
MESSAGE: None
107 CLAS0005 CAUSE: Probe reply ID does not match any probe ID on the IP Probe
wait queue.
ACTION: Informative.
MESSAGE: None
109 CLAS0002 CAUSE: Received a buffer reply message on the wrong subqueue or not
in a buffer reply wait state. This message indicates that this buffer was
not allocated (PARM = buffer reply result code).