NS3000/iX Error Messages Reference Manual (36923-90041)
Chapter 19 383
Logging Location Codes
NS Configurator Logging Location Codes
MESSAGE: INTERNAL ERROR; Internal resource error
9 CLAS0002 CAUSE: When NETCP attempted to create a new protocol module for
an existing NI, after successfully creating a message port for the
module and sending other messages to it, an error occurred while trying
to send an Information message (PARM = 32-bit status returned by the
call to send_msg).
ACTION: There may be a problem with the Ports subsystem of MPE or
a bug in the Module Configurator. SeeAppendix A, “Submitting an SR,”
of this manual.
MESSAGE: INTERNAL ERROR; Internal resource error
11 CLAS0002 CAUSE: When NETCP attempted to create a new NI or a new protocol
module for an existing NI, an error occurred while trying to create a
Port Data Area for the module (PARM = 32-bit status returned by the
call to create_object).
ACTION: There may be a problem with the Ports subsystem of MPE, or
the system may be low on memory. It is also possible bad data in the
NMCONFIG file has caused size calculations to overflow (see Control
Process error 654). Check memory usage and the NMCONFIG file, and
if necessary, see Appendix A, “Submitting an SR,” of this manual.
MESSAGE: INTERNAL ERROR; Internal resource error
12 CLAS0002 CAUSE: When NETCP attempted to create a process for a general
protocol module, an error occurred while trying to start the process
(PARM = 32-bit status returned by the call to createprocess).
ACTION: The program file (i.e., ICMPSERV.NET.SYS) may be missing
or inaccessible, or there may be a problem with the program or with the
Process Management or Loader subsystems of MPE. Check that the file
exists and if necessary, see Appendix A, “Submitting an SR,” of this
manual.
MESSAGE: INTERNAL ERROR; Internal resource error
15 CLAS0002 CAUSE: When NETCP attempted to create an address resolution
protocol module for an existing NI, an error occurred while trying to
obtain the station address of the hardware interface card used by that
NI (PARM = 32-bit status returned by the call to
lan_8023_station_address).
ACTION: There may be an I/O configuration problem, a Link Services
problem, or a problem with the driver or its hardware. Check the
configuration and the hardware and if necessary, see Appendix A,
“Submitting an SR,” of this manual.