NS3000/iX Error Messages Reference Manual (36923-90041)

284 Chapter17
FDDI Error Messages
MESSAGE: FDDI link ! found incorrect HW or SW ID.
73 CAUSE: The FDDI driver found an old or incorrect version of the
firmware or hardware on the FDDI interface card.
ACTION: Update the card to the correct version.
MESSAGE: FDDI link ! could not read hardware ID.
74 CAUSE: The FDDI driver could not read the FDDI hardware
identification codes.
ACTION: Run the diagnostic program to see if the hardware has failed.
If so, replace the card.
MESSAGE: Could not open NMCONFIG file for link !
84 CAUSE: The file NMCONFIG.PUB.SYS does not exist or is not readable.
ACTION: Create NMCONFIG.PUB.SYS with NMMGR.
MESSAGE:
Could not read NMCONFIG file for link !
85 CAUSE: The file NMCONFIG.PUB.SYS either did not exist or was not
readable.
ACTION: Use NMMGR to create a NMCONFIG file. Check that its file
protections are correct.
MESSAGE: NMCONFIG file link ! not validated.
86 CAUSE: NMCONFIG.PUB.SYS was not validated after being updated.
ACTION: Use NMMGR to validate NMCONFIG.PUB.SYS.
MESSAGE: Invalid card at path specified for link !
87 CAUSE: The card, as the configured path, is not an FDDI card.
ACTION: Change your configuration in NMCONFIG.PUB.SYS to the
correct path.
MESSAGE: No card at path specified for link !
88 CAUSE: The FDDI subsystem could not find a card at the configured
path.
ACTION: Change your configuration in NMCONFIG.PUB.SYS to the
correct path.
MESSAGE: FDDI driver already created.
92 CAUSE: The driver was already created under a different linkname, or
by the diagnostic.
ACTION: Check your NMCONFIG.PUB.SYS file and correct it if needed,
or check to see if the diagnostic is running.