NS3000/iX Error Messages Reference Manual (36923-90041)

Chapter 16 239
100VG-AnyLAN and 100Base-T Error Messages
SDI Driver Specific Status Values
adapter card or system HP-PB hardware may have failed. Replace the
adapter card. Then, if the problem still persists, contact your
Hewlett-Packard Service Representative for help in diagnosing your
system hardware.
MESSAGE: Card did not go ready after hard reset.
5000 CLAS0001 CAUSE: After performing a hard reset of the adapter card during
startup, the HP-PB interface chip did not report “ready” status, or
reported an error (“Cause”= 32-bit io_status value read from the
chip).
ACTION: Replace the adapter card.
The link did not start. If the same problem persists even after
replacement with a known good card, contact your Hewlett-Packard
Representative; your software could be out of date, but a patch may be
available. It is unlikely this would be caused by a system HP-PB bus
hardware problem.
MESSAGE: Driver encountered a hardware problem.
5030 CLAS0001 CAUSE: While attempting to alter the loopback mode during diagnostic
testing, the driver read from the network command register on the LAN
controller chip of the adapter card, but encountered an error. Most
likely a power failure has occurred (“Cause”= 32-bit status returned by
the call to vg_dio_read8).
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. But if the same
problem happens every time, see Appendix A, “Submitting an SR.
MESSAGE: Driver encountered a hardware problem.
5060 CLAS0001 CAUSE: While attempting to alter the loopback mode during diagnostic
testing, the driver read from the generic control register on the PHY
chip of the adapter card, but encountered an error. Most likely the PHY
has failed, but a power failure may have occurred (“Cause”= 32-bit
status returned by the call to vg_mii_read16).
ACTION: If a power failure has actually occurred, this error can be
ignored; the driver should recover automatically. Otherwise, the MII
bus may have failed; replace the adapter card. If the same problem
persists, see Appendix A, “Submitting an SR.
MESSAGE: Driver encountered a hardware problem.
5090 CLAS0001 CAUSE: While attempting to alter 100VG-AnyLAN loopback mode
during diagnostic testing, the driver read from the PHY control register
on the PHY chip of the adapter card, but encountered an error. Most
likely the PHY has failed, but a power failure may have occurred
(“Cause”= 32-bit status returned by the call to vg_mii_read16).