NS3000/iX Error Messages Reference Manual (36923-90041)

204 Chapter16
100VG-AnyLAN and 100Base-T Error Messages
SDI Driver Specific Status Values
MESSAGE: Cannot load a system routine.
1170 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to load code
for the write initiator procedure needed for the link type configured in
NMCONFIG (“Cause”= 32-bit status from the call to
hpgetsysplabel).
ACTION: Probably not all software required to operate this type of link
is installed. Software was incorrectly installed, or you may need to
purchase additional software or install newer patches. Reinstall the
link software or contact your Hewlett-Packard Representative for
assistance.
MESSAGE: The link is already started.
1200 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator attempted to create a new instance of the link
driver, but discovered the driver was already created (“Cause”= 32-bit
status from the call to io_configure).
ACTION: This event is informational. No action is required. It probably
would not appear as a log event. The module configurator will ignore
this warning and continue to bring the link driver up, so that the
number of users may be checked. May be followed by another error.
MESSAGE: Cannot add driver to I/O system.
1240 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator attempted to create a new instance of the link
driver, but encountered an error which was not one of the legal errors
the configurator was able to handle (“Cause”= 32-bit status from the
call to io_configure).
ACTION: The module configurator cleaned up and returned an error to
the subsystem.
Verify the path in NMCONFIG is correct and complete, and matches
the path where a supported 100VG-AnyLAN or 100Base-T adapter card
is installed in your computer backplane. If the path passes through bus
converters, verify the SYSGEN configuration has entries for the
higher-level bus converters leading to that path. A diagram of the
backplane slot paths, often found in the rear of your system near the
backplane, may help you. You can also try an offline diagnostic utility
such as MAPPER, or an online utility such as SYSMAP, to precisely
determine your hardware configuration. If necessary, change
NMCONFIG or contact your Hewlett-Packard Representative for
assistance in determining paths or correcting bus hardware problems.
MESSAGE: Cannot open configuration file.
1400 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to open the
configuration file (“Cause”= 32-bit status from the call to nmconfopen).