NS3000/iX Error Messages Reference Manual (36923-90041)
Chapter 16 203
100VG-AnyLAN and 100Base-T Error Messages
SDI Driver Specific Status Values
ACTION: Correct the network configuration or plug in the correct type
of adapter card, and retry the operation. The module configurator
cleaned up and returned an error to the subsystem.
MESSAGE: Cannot create a buffer pool.
1140 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to create an
outbound buffer pool (“Cause”= 32-bit status from the call to
bmgr_create_pool).
ACTION: The system may be low on available memory. The module
configurator cleaned up and returned an error to the subsystem.
Try stopping some applications or sessions and retry the operation. If
the problem persists, stop all networking and restart it, or restart the
system.
The buffer size and pool size are not configurable. If the problem still
occurs, there could be a problem with the buffer manager. See Appendix
A, “Submitting an SR.”
MESSAGE: Cannot create a buffer pool.
1150 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to create a
control buffer pool (“Cause”= 32-bit status from the call to
bmgr_create_pool).
ACTION: The system may be low on available memory. The module
configurator cleaned up and returned an error to the subsystem.
Try stopping some applications or sessions and retry the operation. If
the problem persists, stop all networking and restart it.
The buffer size and pool size are not configurable. If the problem still
occurs, there could be a problem with the buffer manager. See Appendix
A, “Submitting an SR.”
MESSAGE: Cannot load driver plabel.
1160 CLAS0001 CAUSE: During a link-open operation by an upper level subsystem, the
link module configurator encountered an error while trying to load the
code for the driver (“Cause”= 32-bit status from the call to
io_get_mgr_entry).
ACTION: Probably not all software required to operate this type of link
is installed. The software was incorrectly installed, or you may need to
purchase additional software or install newer patches. Reinstall the
link software or contact your Hewlett-Packard Representative for
assistance.