NS3000/iX Error Messages Reference Manual (36923-90041)

160 Chapter15
LAN, LAN/Console, Token Ring LAN Error Messages
MESSAGE: A call to IO_UNCONFIG failed during driver
deconfiguration.
235 CAUSE: Wrong physical path was specified in IO_UNCONFIG call due to
configuration data corruption in the driver PDA.
ACTION: Write down the error information displayed on the console,
submit an SR, take a system dump, and call your Hewlett-Packard
representative.
MESSAGE: The LAN card is used by another link.
236 CAUSE: The card was configured by another link.
ACTION: Use NMMGR to correct the Physical Path for this link or
change the link name to point to a different LAN card.
MESSAGE: Could not create inbound buffer pool for the CIO LAN
card.
237 CAUSE: The buffer manager cannot allocate a new logical buffer pool
entry or cannot allocate virtual memory for the buffers.
ACTION: Write down the error information displayed on the console
and call your Hewlett-Packard representative.
MESSAGE: Could not delete the CIO LAN card inbound buffer pool.
238 CAUSE: Wrong pool ID was specified in the call to delete inbound buffer
pool due to configuration data corruption in the driver's PDA.
ACTION: Write down the error information displayed on the console
submit an SR, take a system dump, and call your Hewlett-Packard
representative.
MESSAGE: Could not open trace file.
239 CAUSE: The indicated trace file might be opened with exclusive access.
ACTION: Wait for the program or process that has the trace file opened
exclusively to close it.
MESSAGE: Could not stop trace.
240 CAUSE: Tracing might have been turned off with LINKCONTROL
TRACEOFF command, but the link software information indicates that it
was on.
ACTION: Ignore this problem unless you are experiencing other
problems. If you are experiencing other problems, write down the error
information displayed on the console and call your Hewlett-Packard
representative.
MESSAGE: Could not start trace.
241 CAUSE: Unknown. Need more information.