NS3000/iX Error Messages Reference Manual (36923-90041)

142 Chapter14
VALERR and VALWARN Messages
ACTION: This is not a problem if one of the LAP-B links configured for
this path is not activated. However, if a LAP-B link is brought up while
another such link is active at that physical path, an error will result
during link startup.
MESSAGE: X.25 INACTIVITY TIMER IS LESS THAN OR EQUAL TO
TCP CONNECTION ASSURANCE TIMER.
1102 CAUSE: The X.25 timer is set too low.
ACTION: Hewlett-Packard recommends that the X.25 Inactivity timer
be configured with a value greater than that of the TCP Connection
Assurance timer to avoid unnecessary closing and opening of the X.25
virtual circuit. For optimum performance, configure the X.25 Inactivity
timer (or the TCP Connection Assurance timer) so that the X.25 timer
has a greater value than the TCP timer.
MESSAGE: SVCPATH HAS NO X.25 ADDRESS—THIS IS VALID ONLY
FOR DDN.
1103 CAUSE: At least one SVCPATH entry does not have an X.25 address key
configured. This configuration will work only if the link is connected to
a DDN.
ACTION: If the link is not connected to a DDN, make sure all SVCPATH
entries have an address key configured under the path
NETXPORT.NI.NIname.PROTOCOL.X25.SVCPATH.