NS3000/iX Error Messages Reference Manual (36923-90041)

Chapter 12 125
NETXPORTERR Error Messages
ACTION: Ensure that the DTC name and card number configured for
this device are correct. Using the Openview DTC Manager, start X.25
for the appropriate DTC and card.
MESSAGE: HOST LOST CONTACT WITH DTC FOR DEVICE linkname.
4210 CAUSE: The control connection between the host and the DTC was lost.
ACTION: Verify that the DTC configured for this device is still
functioning.
MESSAGE: INVALID CARD NUMBER FOR DTC FOR DEVICE
linkname.
4211 CAUSE: This error could occur for one of the following reasons:
The card number specified does not exist on the DTC.
The card number specified is not an X.25 card.
The card number specified has not been configured using the
Openview DTC Manager.
ACTION: Ensure that the DTC name and card number configured for
this device are correct. Using the Openview DTC Manager, configure
and start X.25 for the appropriate DTC and card.
MESSAGE: COULD NOT GET DATA FROM NMCONFIG PATH
“DTS.DTCPC”.
4212 CAUSE: The path DTS.DTC was created, but no data was added.
ACTION: Using NMMGR, update the path and validate the DTS
subsystem.
MESSAGE: LAN LINK NAME NOT CONFIGURED IN NMCONFIG PATH
“DTS.DTCPC”.
4213 CAUSE: The path DTS.DTC was created in NMCONFIG.PUB.SYS, but
the IEEE 802.3 link name was not added.
ACTION: Using NMMGR, update the path and validate the DTS
subsystem.
MESSAGE: COULD NOT GET DATA FROM NMCONFIG PATH
“LINK.linkname”.
4214 CAUSE: The path LINK.linkname was created in NMCONFIG.PUB.SYS,
but no data was added.
ACTION: Using NMMGR, update the path and validate the DTS
subsystem.
MESSAGE: DTC NAME NOT CONFIGURED IN NMCONFIG PATH
“LINK.linkname”.
4215 CAUSE: The path LINK.linkname was created in NMCONFIG.PUB.SYS,
but the DTC name was not added.