NetBase for MPE Reference Guide
System Operations and Maintenance
11-7
FOS Upgrades
When you replace the operating system, you must re-install NetBase.
Action Enter Explanation
Flush the
pipeline
(optional)
:RUN
NBFLUSH.PUB.NETBASE,STOPWAIT;PARM=
shadownode
(on the master node)
This step applies to shadowing
environments only, and it is
optional for those. If performed,
it will force all updates in the
shadowing pipeline to post to
the shadow files, giving you a
sync point at which time both
the master and shadow data
matches.
Stop NetBase
:RUN NBCTRL.PUB.NETBASE;INFO="STOP
NETBASE"
This step gracefully stops all
NetBase activities, including
NFA, shadowing, AutoRPM
and remote spooling.
Disable
NetBase and
the
NMCMDUDC
:RUN NBVERS.PUB.NETBASE,DISABLE
:SETCATALOG
NMCMDCUDC.PUB.NETBASE;SYSTEM
;DELETE
This toggles off the redirection
of CM processes to RTMSL.
Install the new
FOS
per HP's instructions
Reinstall
NetBase shell
:HELLO MANAGER.SYS,PUB
:RUN
NBINST.PUB.NETBASE;INFO="INSTALL"
(reboot the system)
:SETCATALOG NMCMDUDC.PUB.NETBASE;
SYSTEM;APPEND
This puts the NetBase shell in
place to intercept Image
intrinsics.