MPE/iX Intrinsics Reference Manual (32650-90875)
Chapter 4 101
Command Definitions (ABORTSESS - FCLOSE)
DMOVOUT
ARA[13], are moved to half word offset 201 through 204 of the data segment, as shown in
<Undefined Cross-Reference>.
Figure 4-2. DMOVOUT Data Movement.
ARA[1..n] Extra Data Segment
1 +--------------+ 0 +--------------+
2 |--------------| 1 |--------------|
3 |--------------| 2 +--------------+
4 |--------------| .
5 |--------------| .
6 |--------------| .
7 |--------------|
8 |--------------| 199 +--------------+
9 |--------------| 200 |--------------|
10 |--------------| ------> 201 |--------------|
11 |--------------| ------> 202 |--------------|
12 |--------------| ------> 203 |--------------|
13 |--------------| ------> 204 +--------------+
14 +--------------+ +--------------+
+--------------+ .
. .
. .
+--------------+ +--------------+
n +--------------+ 209 +--------------+
Condition Codes
CCE (2) Request granted.
CCG (0) Request denied. Out of bounds-check failure.
CCL (1) Request denied. Illegal
index
or
number
parameter.
Related Information
Intrinsics DMOVIN
Manual Introduction to MPE XL for MPE V Programmers