MPE/iX Error Messages Manual Vol 3 (32650-90880)

302 Chapter7
TurboIMAGE/XL V iii C 5
Utility Error Messages
MESSAGE HARD TERMINAL READ ERROR, TERMINATING
CAUSE DBUTIL cannot read input from terminal.
ACTION Notify HP Support Representative.
MESSAGE ***INVALID SET COUNT***
CAUSE TurboIMAGE/XL found an inconsistency in the data set count.
ACTION Notify HP Support Representative.
MESSAGE MOVE OF FILE
x
NOT ALLOWED: FILE IS NOT CORRECT TYPE (FILE
CODE #)
CAUSE The file specified is not a database file.
ACTION Try the MOVE operation again with the correct file name.
MESSAGE NO MANUAL ENTRY FOR DETAIL ON PATH #
n
CAUSE DBLOAD is attempting to load detail data set entry n, which is the
number of the detail data set path referencing the manual master in
question.
ACTION Add entry to manual master with application program or QUERY. Run
DBLOAD again.
MESSAGE RECSIZE MUST BE <=
xxxx
AND EVENLY DIVISIBLE BY 256.
CAUSE Issued if REC= recsize parameter for DBSTORE specified a record size not
modulo 256 halfwords, or greater than the configured record size of the
device.
ACTION Check the REC= recsize parameter and correct it before running
DBSTORE again.
MESSAGE ROLLBACK LOG FILE MUST BE IN THE SAME VOLUME SET AS THE
DATABASE
CAUSE MPE/iX transaction recovery requires that the MPE/iX user log file must
reside on the same volume set as the database.
ACTION Build the MPE/iX user log file in the same volume set as the database.
NOTE: Because all files in a group are in the same volume set, the MPE/iX
command LISTGROUP indicates the volume set where the database
resides.
MESSAGE SWITCH TO NM TO ATTACH DATABASE TO XM LOG FILE FAILED: XM
ERROR
nn
CAUSE It is necessary to switch to NM to "attach" the database to the MPE/iX
recovery system. The switch failed. nn is the switch to NM error number
returned.
ACTION Notify HP Support Representative.
MESSAGE SWITCH TO NM TO DETACH DATABASE FROM XM LOG FAILED: SWITCH
ERROR
nn
CAUSE It is necessary to switch to NM to "detach" the database from the MPE/iX