MPE/iX Error Messages Manual Vol 3 (32650-90880)
246 Chapter6
TurboIMAGE/XL V iii C 5
Schema Processor Error Messages
Schema Processor again.
MESSAGE SET HAS NO PATHS AVAILABLE
CAUSE More detail data set search items have specified a relationship with a
master data set than the number specified in the master set's path count.
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE SORT ITEM OF BAD TYPE
CAUSE Data item defined as sort item must be of type U, K, or X.
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE SORT ITEM NOT IN DATA SET
CAUSE Detail data set's entry definition does not include an item which is
specified as a sort item for another item in the entry.
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE SORT ITEM SAME AS SEARCH ITEM
CAUSE The same item cannot be both a search and a sort item for the same path.
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE TOO MANY DATA ITEMS
CAUSE The item part of schema cannot have more than 1023 data item names
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE TOO MANY DATA SETS
CAUSE The database cannot have more than 199 data sets.
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE TOO MANY ERRORS
CAUSE The specified or default number of errors has been exceeded. Processing is
terminated.
ACTION Correct the errors, or increase the ERROR parameter value.
MESSAGE TOO MANY ITEMS SPECIFIED
CAUSE The data set entry cannot have more than 255 data items.
ACTION Examine the schema text file to find the error and edit the file. Run the
Schema Processor again.
MESSAGE TOO MANY PATHS IN DATA SET
CAUSE Detail data set entries cannot have more than 16 search items.