MPE/iX Error Messages Manual Vol 3 (32650-90880)

Chapter 5 211
Error Messages V iii C 4
TermDSM
connections, terminal configuration, etc.
(TDSM 229)
CAUSE No or too few characters came back from the loopback.
ACTION If this is an internal loopback, this indicates a hardware
problem. Contact your HP support representative. You can
obtain additional information by running the card selftest
(through the SIC subcommand of the TermDSM RESET
command), the DTC selftest, and the DTC offline
diagnostics. If this is an external loopback, check the
loopback hood to verify that it is securely connected and on
the correct port. If this is a terminal loopback, verify that a
supported, powered on terminal is securely connected to
the proper port. Check baud rate, parity, etc. Note that the
terminal configuration must match the configuration file,
not the state the terminal was in when it was last used. If
this does not help, run internal, then external loopback to
discriminate between a DTC problem and a
terminal/cabling problem.
230 MESSAGE Alternate end-of-record received. Time = xx
msec. (TDSM 230)
CAUSE Probable hardware failure.
ACTION Contact your HP support representative. You can obtain
additional information by running the card selftest
(through the SIC subcommand of the TermDSM RESET
command), the DTC selftest, and the DTC offline
diagnostics.
231 MESSAGE Subsystem break. Time = xx msec. (TDSM 231)
CAUSE Probable hardware failure.
ACTION Contact you HP support representative. You can obtain
additional information by running the card selftest
(through the SIC subcommand of the TermDSM RESET
command), the DTC selftest, and the DTC offline
diagnostics.
232 MESSAGE No modem was connected during the operation.
Time = xx msec. (TDSM 232)
CAUSE During the test, the modem on that port was disconnected.
ACTION Reconnect the modem and try the test again. If the failure
continues, or if there was no modem in use on that port,
there is a probable hardware failure. Contact your HP
support representative. You can obtain additional
information by running the card selftest (through the SIC
subcommand of the TermDSM RESET command), the DTC
selftest, and the DTC offline diagnostics.