MPE/iX Error Messages Manual Vol 3 (32650-90880)

Chapter 3 101
Error Messages Viii C 3
Native Mode Device File
corresponding delimiters must be present.
ACTION Adhere to required syntax. The INFO string for this
program must contain a minimum of two parameters. If
you need help on syntax, type "HELP MSGUTIL".
516 MESSAGE The name for the specified subsystem could
not be obtained.
CAUSE The user has provided a subsystem number which is not in
the System Catalog.
ACTION Check the System Catalog or use the right number.
534 MESSAGE Unable to display Message #
ACTION Information only.
550 MESSAGE WARNING - Time/date display capabilities
could not be activated.
CAUSE The program could not adequately initialize range
checking for time codes. Therefore, time code conversions
will not be accepted. This error is unexpected and may be
system dependent.
ACTION Other functions of the program will continue to function.
Notify your support engineer.
551 MESSAGE WARNING - Extra, unused parameters were
specified in the INFO string.
CAUSE More than three parameters have been supplied.
MSGUTIL ignored all past those first three.
ACTION Adhere to the required syntax.
Native Mode Device File
(Subsystem 231 NMDF WARN, NMDF ERR)
-1 MESSAGE An invalid call to either Get or
Set_device_information has
occurred. No return parameter was provided
for a requested return
item.
-2 MESSAGE An invalid call to either Get or
Set_device_information has occurred.
An item number was specified that is not a
valid item for Get or
Set_device_information.