MPE/iX Error Messages Manual Vol 2 (32650-90879)

Chapter 8 313
System Startup, Shutdown, and Configuration
Class Errors
x = Device address (always 0 for the console)
y = CIO mid-bus slot number
zz = IODC driver error code 00 - 7F.
0100 9y80 MESSAGE None.(I)
CAUSE I/O dependent code (IODC) from channel I/O bus (CIO) in
console path fails.
ACTION None. If problem recurs or is suspected cause of a future
system problem or failure, contact your Hewlett Packard
Support Representative.
0100 9y88 MESSAGE No message. System halts. (E)
CAUSE No working console is found. Autoboot disabled.
ACTION Connect console or replace existing console. Reboot
system.
01C0 9yzz MESSAGE No message. Self-test continues. (W)
CAUSE Access port self-test fails. "zz" = AP self-test code (00-7F).
ACTION If AP not functional, reset the system from the front panel.
If a soft reset/transfer of control is needed, set switch 3 on
the system monitor card to the open position and reset the
system from the front panel. If AP is functional and can
reset the system, note the error as a possible console path
or CIO bus problem should a future problem or system
failure occur.
01C0 9yF0 MESSAGE No message. Self-test continues. (W)
CAUSE Access port read of the hexadecimal display fails.
ACTION None. Note error should a future system problem occur.
01C0 9yFF MESSAGE No message. Self-test continues. (W)
CAUSE No access port is found.
ACTION If an access port exists and remains functional, note error
should the problem cause a future problem or system
failure. If AP is disabled or not functioning and you have
reset the system from the front panel, ignore warning
message.