userpass
User password, optionally assigned by the account manager. The password
must contain from one to eight alphanumeric characters, beginning with
an alphabetic character. The user password must be preceded by a slash
(/).
acctname
Account name as established by the system manager. The name must
contain from one to eight alphanumeric characters, beginning with an
alphabetic character. The
acctname
parameter must be preceded by a
period (.).
acctpass
Account password, optionally assigned by the system manager. The
password must contain from one to eight alphanumeric characters,
beginning with an alphabetic character. The account password must be
preceded by a slash (/).
groupname
Group name to be used for the local file domain and the CPU and
connect-time charges as established by the account manager. The name
must contain from one to eight alphanumeric characters, beginning with
an alphabetic character. Default is your home group if you are assigned
one by the account manager. (Required if a home group is not assigned.)
grouppass
Group password optionally assigned by the account manager. The
password must contain from one to eight alphanumeric characters
beginning with an alphabetic character. The
grouppass
parameter is not
needed to log on to your home group. The group password must be
preceded by a slash (/).
termtype
or
termname
Determines terminal type characteristics. The
termtype
parameter determines the type of terminal used for input. MPE/iX uses
this parameter to determine device-dependent characteristics such as
delay factors for carriage returns. It must be 10 or 18. The default value
for
termtype
is assigned by the system supervisor during system
configuration. This is a required parameter to ensure correct listings if
your terminal is not the default
termtype
.
The
termname
parameter is the name of the file containing the desired
terminal-type characteristics. The file cannot have a lockword or reside on
a user volume.
Users of the workstation configurator are allowed to create terminal-type
files. The proper and efficient operation of a specific device by a
user-created terminal type is the responsibility of the user. The
workstation configurator utility allows the user to specify characteristics
of the terminal, including data flow control, block mode, read trigger,
special characteristics, echo, line feed, parity, and printer control.
cpusecs
Maximum CPU-time that a session can use, entered in seconds. When the
limit is reached, the session is aborted. It must be a value from 1 to 32767.
To specify no limit, enter a question mark (?), UNLIMITED, or omit the
parameter. Default is no limit.
BS, CS, DS, or ES The execution priority queue that MPE/iX uses for your session, and also