Installing and Managing HP ARPA File Transfer Protocol Network Manager's Guide (36957-90157)

104 Appendix C
PING/iX Utility
PING/iX Error and Information Messages
PING/iX Error and Information Messages
In addition to the normal reply message details and statistics, PING/iX
can display informational and/or error messages which are described
below.
MESSAGE: Receive timeout occurred. Shutting Down. . .
CAUSE: The PING/iX process has not received any response to its
requests for two minutes. So it shuts itself down, assuming that the
local or the remote side is inactive.
ACTION: This could indicate that the remote node is unreachable. Also
check if the local node is congested or hung causing the local ICMP
Server not to respond. (The local ICMP Server interacts with PING/iX
to send ICMP Echo Requests to the remote, and passes incoming replies
to the right PING/iX process.)
MESSAGE: Cannot contact local ICMP Server. Shutting down. . .
CAUSE: PING/iX cannot contact the above mentioned local ICMP
Server.
ACTION: Check if the Transport is active. If not, start the transport.
MESSAGE: Server not accepting requests, as it is busy. Please try
later.
CAUSE: Only 15 PING/iX processes can be active at any time. That is,
only 15 users can run PING/iX at the same time. Additional users
trying to run PING/iX will get this error message.
ACTION: Wait, and try later. One of the other PING/iX processes might
have completed, allowing you to run the program.
MESSAGE: Cannot resolve path to remote. Path Error, Parm_Value.
Refer PATH RESULT CODES table in NS 3000/iX Error Messages
Manual.
CAUSE: A suitable path out of the local node to reach the remote node
could not be found.
ACTION: Look up the table mentioned in the message, under the
Parm_Value code, and take the action recommended therein.
MESSAGE: Arithmetic trap Parm. Program Quitting
CAUSE: This is an internal error.
ACTION: Submit an SR with the Parm value, a description of what you
were trying to do, and any other error messages printed on the
terminal. To submit an SR, see the NS 3000/iX Operations and
Maintenance Manual.