HP RPG/iX Utilities Reference Manual (30318-90006)

B-102
Syntax Messages
General Errors
Header Errors
NUMBER MESSAGE FURTHER EXPLANATION
202 INVALID SPECIFICATION TYPE-
COL 6 MUST BE H, I, O, OR F
Only exceptions are ALTSEQ records.
1001 MORE THAN ONE HEADER SPEC XSORT specifications must begin with one, and only
one, header specification.
1004 BEGIN/END COLUMN MISSING
OR INVALID NUMERIC
For both Record Type and Field Description specifi-
cations, the "Location From/To" entries in columns 9-
16 must contain valid numeric values.
1005 BEGIN COL>END COL OR END
COL OUTSIDE OF RECORD
For both Record Type and Field Description specifi-
cations, the "Location From" entry in columns 9-12
must not be greater than the "To" entry in columns 13-
16. Also, the "To" value must not exceed the actual
record length of the XSORTIN file.
1012 BEGIN COL MUST BE BLANK "From location" (Columns 9-12) must be blank or the
same as "To location" (Columns 13-16) for condition-
ally forced control fields.
NUMBER MESSAGE FURTHER EXPLANATION
103 MUST BE SORTA, SORTC,
OR SORTR
Columns 7-12 must contain SORTA, SORTC, or SORTR.
151 NO CONTROL FIELD
LENGTH SPECIFIED
Columns 13-17 must contain the largest sum of control field
lengths of any record section (in bytes)
162 INVALID NUMBER IN OUT-
PUT RECORD LENGTH
FIELD
Columns 29-32 must contain a valid numerical value.
1002 BAD KEY RETENTION OPT-
-MUST BE BLANK OR X
Column 28 must contain either a blank, to retain control
fields on output records, or "X" to drop the control fields.
1003 ASCENDING/DESCENDING
OPT INVALID-COL 18 MUST
BE A OR D
ALTSEQ MUST BE S OR
BLANK -COL 26
1025 PRINT OPTION (COL 27)
MUST BE 0, 1, 2, OR 3